  • This all-round single-piece nitinol navigation wire adopts gradient tapered distal design paired with exclusive full-distal M-Coat hydrophilic polymer layer, realizing lossless 1:1 full-length torque response across three major vascular systems. Integrated tungsten-doped polyurethane outer jacket delivers continuous low-dose fluoroscopic visibility, with standard, stiff and golden coil GT sub-models to match mild calcification, heavy plaque and ultra-fine distal neuro vessel clinical demands respectively.
    Read More
  • Maejet Peripheral-35 is an over-the-wire (OTW) PTA balloon catheter compatible with 0.035-inch guidewires. It features an ultra-slender 0.040-inch atraumatic tip and proprietary tack-weld reinforced shaft, delivering superior pushability and lesion-crossing performance for medium-to-large peripheral vessels including iliac, femoral and popliteal arteries. Its 5-fold semi-compliant balloon pairs with selective distal hydrophilic coating. The coaxial large inflation lumen enables industry-leading rapid deflation performance. Balloon diameters range from 3-12 mm; working shaft lengths 75 cm /100 cm /135 cm. Indicated for stenoses & occlusions of iliac, femoral, popliteal, renal arteries as well as peripheral stent post-dilatation procedures.
    Read More
  • Amplatz Super Stiff adopts enlarged solid stainless inner core paired with flat-wound outer coil architecture to deliver unmatched whole-shaft rigidity, dedicated as secondary support exchange wire for heavy sheath, large stent and dilator advancement across thick-walled luminal systems. Full integrated dry PTFE friction-reducing coating eliminates pre-hydration demand; multiple factory preset non-reshapeable atraumatic tip profiles balance supreme shaft stability and distal vessel safety for urologic, peripheral vascular and biliary interventional workflows.
    Read More
  • This frontline coronary navigation wire adopts proprietary multi-wound composite core architecture to deliver synchronous lag-free torque transmission paired with stable medium shaft rigidity, forming balanced trackability and support for daily elective single-vessel PCI. Equipped with 28cm full distal SLIP lubrication film and fixed 0.7gf mild tip load, it retains consistent soft tactile feedback and long-term tip shaping stability during repeated crossing of non-calcified and mild stenotic coronary lesions.
    Read More
  • The Interventional Y-shaped Adapter is a multi-functional accessory for various interventional surgeries. It realizes good hemostasis, flexible operation and full compatibility with mainstream interventional devices, and the side port enables injection and pressure monitoring. As a disposable sterile device with high pressure resistance, it is a common tool in catheterization labs.
    Read More
  • Designed for PTCA and PCI, this inflation device is equipped with a high-precision pressure gauge, safety lock and kink-resistant tube. It supports convenient one-hand operation, works with mainstream balloon catheters and is widely used in cardiovascular minimally invasive interventions.
    Read More
  • Dual-layer balloon burst pressure up to 36atm, minimal entry OD 0.0158”, multi-fold construction optimized for severe calcified hard plaque. Distal hydrophilic coating engineered for coronary & peripheral heavily calcified lesion angioplasty, powerful dilation for fibro-calcified stenosis.
    Read More
  • Maejet Peripheral-18 is an over-the-wire (OTW) peripheral balloon catheter compatible with 0.018-inch guidewires. It features proprietary tapered-profile balloons matching the natural tapering anatomy of below-the-knee (BTK) arteries. The 0.020-inch bidirectional laser-formed atraumatic tip and tack-weld reinforced shaft deliver superior crossability and retrievability across tortuous long lesions. Selective hydrophilic coating on the balloon body minimizes advancing friction. Offering balloon diameters from 1.5-6.0 mm, this device supports angioplasty for long stenotic or occlusive lesions above and below the knee, optimising vessel preparation and lowering dissection risks.
    Read More
  • Ultra-small entry outer diameter down to 0.0158”, multi-fold balloon with heat treatment process, coaxial /dual push rod optional. Distal selective hydrophilic coating covers coronary, peripheral and intracranial stenosis dilation, balloon diameter range 1.0–12mm for calcified & non-calcified angioplasty.
    Read More
  • Independently engineered Maejet micro guidewire features an integrated nickel-titanium stainless steel composite core to deliver synchronous 1:1 torque transmission without response lag. Full-length uniform medical hydrophilic coating paired with customizable pre-shaped tips minimizes vascular friction trauma during intricate coronary and peripheral vascular surgeries.
    Read More
  • This indwelling ureteral stent adopts symmetrical pigtail design for firm anchorage. Made of medical polymer, it has multiple drainage holes, reliable kink resistance and clear radiopacity, and the optional hydrophilic coating further optimizes use experience for various urological treatments and postoperative drainage.
    Read More
  • V-Loc 180 is a premium knotless absorbable barbed wound closure device originally launched, complete absorption is achieved within approximately 180 days in-vivo. It adopts innovative unidirectional barb design, eliminating the need for traditional knot tying during surgery. As a mainstream long-term absorbable surgical suture, it features stable tensile strength, safe and complete absorption, wide surgical adaptability, and is widely recognized by global hospitals and aesthetic surgery institutions.