Enter product details (such as color, size, materials etc.) and other specific requirements to receive an accurate quote.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
other

Products

  • This all-round single-piece nitinol navigation wire adopts gradient tapered distal design paired with exclusive full-distal M-Coat hydrophilic polymer layer, realizing lossless 1:1 full-length torque response across three major vascular systems. Integrated tungsten-doped polyurethane outer jacket delivers continuous low-dose fluoroscopic visibility, with standard, stiff and golden coil GT sub-models to match mild calcification, heavy plaque and ultra-fine distal neuro vessel clinical demands respectively.
    Read More
  • Amplatz Super Stiff adopts enlarged solid stainless inner core paired with flat-wound outer coil architecture to deliver unmatched whole-shaft rigidity, dedicated as secondary support exchange wire for heavy sheath, large stent and dilator advancement across thick-walled luminal systems. Full integrated dry PTFE friction-reducing coating eliminates pre-hydration demand; multiple factory preset non-reshapeable atraumatic tip profiles balance supreme shaft stability and distal vessel safety for urologic, peripheral vascular and biliary interventional workflows.
    Read More
  • This frontline coronary navigation wire adopts proprietary multi-wound composite core architecture to deliver synchronous lag-free torque transmission paired with stable medium shaft rigidity, forming balanced trackability and support for daily elective single-vessel PCI. Equipped with 28cm full distal SLIP lubrication film and fixed 0.7gf mild tip load, it retains consistent soft tactile feedback and long-term tip shaping stability during repeated crossing of non-calcified and mild stenotic coronary lesions.
    Read More
  • The Interventional Y-shaped Adapter is a multi-functional accessory for various interventional surgeries. It realizes good hemostasis, flexible operation and full compatibility with mainstream interventional devices, and the side port enables injection and pressure monitoring. As a disposable sterile device with high pressure resistance, it is a common tool in catheterization labs.
    Read More
  • Designed for PTCA and PCI, this inflation device is equipped with a high-precision pressure gauge, safety lock and kink-resistant tube. It supports convenient one-hand operation, works with mainstream balloon catheters and is widely used in cardiovascular minimally invasive interventions.
    Read More
  • Ultra-small entry outer diameter down to 0.0158”, multi-fold balloon with heat treatment process, coaxial /dual push rod optional. Distal selective hydrophilic coating covers coronary, peripheral and intracranial stenosis dilation, balloon diameter range 1.0–12mm for calcified & non-calcified angioplasty.
    Read More
  • Independently engineered Maejet micro guidewire features an integrated nickel-titanium stainless steel composite core to deliver synchronous 1:1 torque transmission without response lag. Full-length uniform medical hydrophilic coating paired with customizable pre-shaped tips minimizes vascular friction trauma during intricate coronary and peripheral vascular surgeries.
    Read More
  • This indwelling ureteral stent adopts symmetrical pigtail design for firm anchorage. Made of medical polymer, it has multiple drainage holes, reliable kink resistance and clear radiopacity, and the optional hydrophilic coating further optimizes use experience for various urological treatments and postoperative drainage.
    Read More
  • V-Loc 180 is a premium knotless absorbable barbed wound closure device originally launched, complete absorption is achieved within approximately 180 days in-vivo. It adopts innovative unidirectional barb design, eliminating the need for traditional knot tying during surgery. As a mainstream long-term absorbable surgical suture, it features stable tensile strength, safe and complete absorption, wide surgical adaptability, and is widely recognized by global hospitals and aesthetic surgery institutions.
    Read More
  • Microcatheter with optional 3/4-layer construction, dual mid-layer options of braid or coil spring; gradual shaft density balances support and conformability. Tapered radiopaque tip boosts crossing capacity through severe stenoses, multi-gradient outer jacket optimized for neuro, oncology and peripheral CTO superselective embolization. Full hydrophilic coating enables smooth navigation inside highly tortuous tiny vasculature.
    Read More
  • Compatible with radial and femoral artery approaches, the sheath features thin-wall large-lumen design, excellent kink resistance and low-friction hydrophilic coating for safe insertion. Equipped with a hemostatic valve and three-way stopcock, it supports multiple intraoperative operations and serves as a basic device for coronary and peripheral vascular interventions.
    Read More
  • Multi-layer braided angiographic catheter features multi-gradient shaft rigidity and high radiopaque atraumatic tip, supporting high-pressure contrast injection up to 1000PSI for routine coronary & peripheral diagnostic angiography. Options include full-length PTFE or hydrophilic coating drastically reduces intimal friction trauma, with full range of pre-shaped curves matching mainstream vascular anatomies.
    Read More
1 2 3
A total of3pages