The HI-TORQUE PILOT 50 Specialty Guide Wire with Hydrophilic Coating

The HI-TORQUE PILOT 50 Guide Wire is a high-performance guide wire dedicated to coronary and peripheral vascular interventions. Constructed with DURASTEEL high-strength stainless steel core and full polymer cover, it delivers outstanding kink resistance and long-term durability. Adopting core-to-tip design, it realizes 1:1 accurate torque response for sensitive manipulation and stable steering. The distal 3 cm platinum-nickel radiopaque segment and durable PVP hydrophilic coating greatly reduce friction to ensure smooth advancement and withdrawal. With a lightweight 1.5g soft tip that is manually shapeable and optionally pre-formed into J-shape, it combines superior trackability and lesion crossing performance. It is capable of navigating tortuous vessels, severe stenosis and chronic total occlusions (CTO), serving as a primary workhorse guide wire for lesion crossing and device delivery in coronary and peripheral interventional procedures.

  • Intended Use :

    CTO
  • Total Length :

    190cm / 300cm
  • Outer Diameter :

    0.014” (0.36 mm)
  • Distal Core Material :

    Nitinol
  • Cover Type or Coils :

    Full Polymer Cover
  • Tip Style :

    Core-to-tip
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    1.3
  • Radiopaque length :

    3cm
  • Tip Shape :

    Straight / J
  • Usage Type :

    Single Use Only

Product Overview

The HI-TORQUE PILOT 50 Guide Wire is meticulously developed for complex coronary and peripheral vascular procedures. It is built with premium DURASTEEL stainless steel core and integrated polyurethane polymer cover, featuring stable structure and excellent bend resistance without deformation during prolonged use. This guide wire adopts a dual-coating system: the distal 25.6 cm section is coated with PVP hydrophilic material, while the proximal section uses PTFE coating to balance lubricity and push stability and minimize the risk of vascular mucosal injury. The 3 cm platinum-nickel radiopaque segment at the distal end provides clear fluoroscopic visibility for real-time monitoring of guide wire position and depth during operations. Equipped with professional parabolic core grind and core-to-tip structure, it achieves lossless torque transmission and synchronous response to manipulation. The soft and shapeable tip maintains stable shape effectively, enabling the wire to cross bifurcation lesions, moderately to severely tortuous vessels, severe stenosis and chronic total occlusions. It is widely used for balloon dilatation, stent delivery and device exchange with consistent and reliable overall performance.


Key Highlights

  • Dual Coating System: Distal PVP hydrophilic coating greatly reduces friction, and proximal PTFE coating ensures stable pushing for smooth navigation and less vascular damage.
  • Precise Torque Transmission: Core-to-tip design and parabolic core grind deliver 1:1 torque response for accurate steering and easy manipulation.
  • Superior Kink Resistance: DURASTEEL stainless steel core and full polymer cover form a robust structure to resist repeated bending for complex vascular access.
  • Lightweight Soft Tip: 1.5g low-load soft tip supports manual intraoperative shaping; pre-formed J-shape is optional to enhance procedural safety.
  • High-visibility Radiopaque Design: The 3 cm platinum-nickel radiopaque segment ensures clear fluoroscopic visualization and reduces repeated imaging and radiation exposure.
  • Excellent Lesion Crossing Capacity: Balanced support and trackability enable efficient crossing of stenosis, tortuous vessels, bifurcation lesions and chronic total occlusions (CTO).
  • Universal Device Compatibility: Smooth overall surface is fully compatible with balloons, stents and other interventional devices for steady delivery.

Technical Specifications & Construction

The distal tip can be manually shaped during surgery, and pre-formed J-shape is available as an option. A 3 cm platinum-nickel radiopaque segment is equipped at the distal end for stable and clear fluoroscopic imaging. The guide wire features a uniform standard diameter of 0.014 inch and two mainstream lengths: 190 cm and 300 cm. Sterilized by electron beam, it is a single-use sterile medical device with individual packaging and a 2-year shelf life.

Coating Distal: Hydrophilic; Proximal: PTFE
Core Material Stainless Steel, Nitinol
Tip / Radiopacity Platinum-Nickel Alloy, 3 cm Radiopaque Segment
Jacket / Cover Full Polyurethane Polymer Cover
Usage Single Use Only


Typical Clinical Applications

Widely adopted as a fundamental guide wire by interventional cardiologists and peripheral vascular specialists, this device is not intended for cerebral vascular procedures. Typical clinical applications are as follows:

  • Conventional Coronary PCI (Percutaneous Coronary Intervention) and Percutaneous Transluminal Coronary Angioplasty (PTCA)
  • Peripheral vascular interventions including Percutaneous Transluminal Angioplasty (PTA)
  • Balloon passage, vascular dilatation, stent delivery and implantation
  • Coronary and peripheral vascular bifurcation lesions, moderately to severely tortuous lesions
  • Recanalization of severe stenosis and de novo chronic total coronary occlusions (CTO)
  • Establishment of initial vascular access and exchange of diagnostic & interventional devices

Quality Assurance & Compliance

Patient safety and consistent clinical performance are our core principles. The HI-TORQUE PILOT 50 Guide Wire is manufactured in internationally standardized cleanrooms in strict accordance with the ISO 13485 medical device quality management system. Each batch undergoes rigorous tests including torque response, coating adhesion, kink resistance, tip shape durability, tensile strength and biocompatibility to ensure stable and consistent performance in catheterization labs. The product complies with global standards for coronary and peripheral interventional medical devices and holds complete compliance qualifications to meet clinical access requirements worldwide.


Ordering Information

We supply high-quality medical consumables to hospitals, clinics, and medical device distributors worldwide. Bulk ordering and customized specifications (OEM/ODM) are available upon request. Please contact our sales team to discuss wholesale pricing, shipping terms, and specific regional compliance documentation.


Frequently Asked Questions (FAQ)

1. Is the HI-TORQUE PILOT 50 Guide Wire suitable for chronic total occlusions (CTO) and tortuous vessels?

Yes. Adopting DURASTEEL stainless steel core and hydrophilic coating, the product has excellent kink resistance, tracking performance and moderate penetration capability. It can efficiently pass through tortuous vasculature, tight stenoses and chronic total occlusions, perfectly coping with various challenging lesions.

 

2. Can this guidewire be re-sterilized and reused?

No. This device is strictly designated for Single Use Only. Re-sterilization and reuse will damage the hydrophilic coating, polymer cover and core structure, and greatly increase clinical risks such as vascular injury and infection. Reuse is prohibited to ensure patient safety.

 

3. Does the tip support manual shaping?

Yes. The 3 cm distal flexible tip is easy to shape. Doctors can manually shape it according to intraoperative demands, and the pre-formed J-shape option is also available to adapt to different vascular anatomies.

 

4. Do you support global shipping and bulk orders?

Absolutely. We partner with reliable international logistics providers to fulfill global B2B orders. Please reach out with your required volume for a customized quote and lead time estimate.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Interventional Guidewire Supplier
The HI-TORQUE COMMAND 18 ST Hybrid Workhorse Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND 18 ST Guide Wire is a hybrid workhorse peripheral guide wire that combines the advantages of nitinol and stainless steel. It features high support, superior kink resistance and long-term durability. Equipped with a 10 cm nitinol segment at the distal end and a flexible tip with 4g tip load, the wire is easy to shape. Adopting parabolic core and transitionless weld design, it delivers highly efficient torque transmission. With balanced pushability, maneuverability and crossing performance, it can effectively cross occlusive lesions and complete subintimal looping procedures, serving as a core workhorse guide wire for lesion crossing and device delivery in peripheral vascular interventions of lower extremities.

Read More
Interventional Guidewire Supplier
The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is a classic hybrid workhorse guide wire. It adopts a composite structure of proximal 304V stainless steel and distal nitinol alloy, delivering robust support, superior kink resistance and long-lasting durability. Featuring core-to-tip design and transitionless fusion weld technology, it achieves full-length 1:1 synchronous torque response for accurate and smooth manipulation. The distal 3 cm platinum-nickel radiopaque coil and long-acting hydrophilic coating greatly reduce friction for smooth advancement. The shapeable nitinol tip maintains stable shape during procedures. It navigates tortuous and stenotic peripheral vessels such as femoral artery, popliteal artery and infra-popliteal artery efficiently, serving as the primary choice for percutaneous transluminal angioplasty, stent implantation and other peripheral interventional procedures.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL II Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL II Guide Wire is a coronary workhorse guide wire developed by Abbott for PCI procedures. It is designed to provide an optimized balance of torque response, trackability, lubricity, and vessel support in routine and moderately complex coronary interventions.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL Guide Wire is a classic coronary intervention guide wire developed by Abbott, widely used for balloon and stent delivery in PCI/PTCA procedures. It is widely recognized worldwide as a "workhorse guidewire" for daily PCI procedures.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) guide wire is designed for kink resistance and durability. BMW family also features moderate support, excellent flexibility, shaping ribbon for easy tip shapeability and core-to-tip design for excellent torque transmission for outstanding control and steering in challenging anatomy.

Read More