Enter product details (such as color, size, materials etc.) and other specific requirements to receive an accurate quote.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
product details

The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is a classic hybrid workhorse guide wire. It adopts a composite structure of proximal 304V stainless steel and distal nitinol alloy, delivering robust support, superior kink resistance and long-lasting durability. Featuring core-to-tip design and transitionless fusion weld technology, it achieves full-length 1:1 synchronous torque response for accurate and smooth manipulation. The distal 3 cm platinum-nickel radiopaque coil and long-acting hydrophilic coating greatly reduce friction for smooth advancement. The shapeable nitinol tip maintains stable shape during procedures. It navigates tortuous and stenotic peripheral vessels such as femoral artery, popliteal artery and infra-popliteal artery efficiently, serving as the primary choice for percutaneous transluminal angioplasty, stent implantation and other peripheral interventional procedures.

  • Intended Use :

    PTA
  • Total Length :

    190cm / 250cm / 300cm
  • Outer Diameter :

    0.014” (0.36 mm)
  • Distal Core Material :

    Nitinol
  • Tip Style :

    Core-to-tip
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    3.5
  • Radiopaque length :

    3cm
  • Tip Shape :

    Straight
  • Usage Type :

    Single Use Only

Product Overview

The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is meticulously developed for complex peripheral vascular interventions and acts as a core workhorse device for lower extremity vascular procedures. The high-strength 304V stainless steel core at the proximal end provides sufficient pushability and overall support to resist kinking. The distal Elastinite nitinol segment offers excellent flexibility and shape retention to adapt to diverse vascular anatomies. The transitionless fusion weld eliminates structural gaps and ensures smooth passage of balloons, stents and other interventional devices. The distal Pellathane hydrophilic coating minimizes friction against vessel walls and reduces the risk of vascular trauma. The 3 cm platinum-nickel radiopaque coil delivers outstanding fluoroscopic visibility for real-time tracking of wire position and depth. With integrated core-to-tip structure, it realizes lossless torque transmission and maintains stable performance in severely tortuous vessels and short-access lesions. It is widely applied for lesion crossing, device exchange and vascular access establishment.


Key Highlights

  • Hybrid Material Structure: The combination of proximal stainless steel and distal nitinol balances support, pushability and kink resistance for all types of lower extremity peripheral vessels.
  • Full-length 1:1 Torque Response: Core-to-tip design and transitionless weld realize synchronous operation response for precise steering and positioning.
  • Long-acting Hydrophilic Coating: Distal Pellathane hydrophilic coating provides superior lubricity for smooth advancement and withdrawal, lowering the risk of mucosal injury.
  • High-visibility Radiopaque Design: The 3 cm platinum-nickel radiopaque coil ensures clear fluoroscopic visualization and reduces repeated imaging and radiation exposure.
  • Durable Shapeable Tip: The nitinol soft tip supports repeated shaping and retains shape steadily during operations to minimize device replacement.
  • Excellent Device Compatibility: The integrated smooth structure enables smooth delivery and exchange of balloon dilatation catheters and stents.
  • Superior Crossing Performance: It navigates tortuous vessels and moderate stenotic lesions efficiently to complete lesion crossing and access establishment.

Technical Specifications & Construction

The distal shapeable soft tip is available in straight and angled styles. A 3 cm platinum-nickel radiopaque coil is equipped at the distal end for clear fluoroscopic imaging. With a standard diameter of 0.014 inch and multiple optional lengths, the guide wire adopts composite hydrophilic coating. Sterilized by electron beam radiation, this is a single-use sterile medical device manufactured under strict standards.

Coating Distal: Hydrophilic; Proximal: PTFE
Core Material Stainless Steel, Nitinol
Tip / Radiopacity Platinum-Nickel Alloy, 3 cm Radiopaque Coil
Jacket / Cover Full Polyurethane Polymer Cover
Usage Single Use Only



Typical Clinical Applications

As a widely recognized workhorse guide wire for peripheral interventional specialists, this device is not intended for coronary or cerebral vasculature. It is mainly used for diagnosis and treatment of lower extremity peripheral vascular diseases:

  • Percutaneous Transluminal Angioplasty (PTA)
  • Placement of balloon dilatation catheters and vascular balloon dilatation
  • Delivery and implantation of peripheral vascular stents
  • Lesion treatment of femoral artery, popliteal artery and infra-popliteal artery
  • Crossing tortuous vessels and moderately stenotic lesions
  • Establishment of target vascular access and exchange of diagnostic & interventional devices

Quality Assurance & Compliance

Patient safety and consistent clinical performance are our core principles. The HI-TORQUE PILOT 50 Guide Wire is manufactured in state-of-the-art cleanrooms in strict accordance with the ISO 13485 medical device quality management system. Every batch undergoes rigorous tests including torque response, coating adhesion, kink resistance, tip shape durability and tensile strength to ensure reliable and stable performance in interventional labs. The product complies with mainstream global medical device safety standards and holds complete compliance qualifications to meet clinical access requirements of various regions.


Ordering Information

We supply high-quality peripheral interventional consumables to hospitals, specialized interventional clinics and medical device distributors worldwide. Bulk orders and combined specification orders are supported, and customized services as well as OEM/ODM cooperation are available upon request. Please contact our sales team for wholesale pricing, shipping terms, lead time and regional compliance certification documents.


Frequently Asked Questions (FAQ)

1. Is this guide wire suitable for tortuous lower extremity peripheral vessels?

Yes. Adopting stainless steel and nitinol hybrid structure, it features excellent kink resistance and flexibility. Combined with low-friction hydrophilic coating, it can smoothly navigate tortuous lower extremity vessels such as femoral artery, popliteal artery and infra-popliteal artery, making it an ideal option for complex peripheral interventions.

 

2. Can this guidewire be re-sterilized and reused?

No. This device is strictly designated for Single Use Only. Re-sterilization and reuse will damage the hydrophilic coating, hybrid core structure and tip performance, and may cause vascular injury, infection and other medical risks. Reuse is prohibited to ensure patient safety.

 

3. Do you support global shipping and bulk orders?

Absolutely. We partner with reliable international logistics providers to fulfill global B2B orders. Please reach out with your required volume for a customized quote and lead time estimate.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Interventional Guidewire Supplier
The HI-TORQUE COMMAND 18 ST Hybrid Workhorse Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND 18 ST Guide Wire is a hybrid workhorse peripheral guide wire that combines the advantages of nitinol and stainless steel. It features high support, superior kink resistance and long-term durability. Equipped with a 10 cm nitinol segment at the distal end and a flexible tip with 4g tip load, the wire is easy to shape. Adopting parabolic core and transitionless weld design, it delivers highly efficient torque transmission. With balanced pushability, maneuverability and crossing performance, it can effectively cross occlusive lesions and complete subintimal looping procedures, serving as a core workhorse guide wire for lesion crossing and device delivery in peripheral vascular interventions of lower extremities.

Read More
Interventional Guidewire Supplier
The HI-TORQUE PILOT 50 Specialty Guide Wire with Hydrophilic Coating

The HI-TORQUE PILOT 50 Guide Wire is a high-performance guide wire dedicated to coronary and peripheral vascular interventions. Constructed with DURASTEEL high-strength stainless steel core and full polymer cover, it delivers outstanding kink resistance and long-term durability. Adopting core-to-tip design, it realizes 1:1 accurate torque response for sensitive manipulation and stable steering. The distal 3 cm platinum-nickel radiopaque segment and durable PVP hydrophilic coating greatly reduce friction to ensure smooth advancement and withdrawal. With a lightweight 1.5g soft tip that is manually shapeable and optionally pre-formed into J-shape, it combines superior trackability and lesion crossing performance. It is capable of navigating tortuous vessels, severe stenosis and chronic total occlusions (CTO), serving as a primary workhorse guide wire for lesion crossing and device delivery in coronary and peripheral interventional procedures.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL II Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL II Guide Wire is a coronary workhorse guide wire developed by Abbott for PCI procedures. It is designed to provide an optimized balance of torque response, trackability, lubricity, and vessel support in routine and moderately complex coronary interventions.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL Guide Wire is a classic coronary intervention guide wire developed by Abbott, widely used for balloon and stent delivery in PCI/PTCA procedures. It is widely recognized worldwide as a "workhorse guidewire" for daily PCI procedures.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) guide wire is designed for kink resistance and durability. BMW family also features moderate support, excellent flexibility, shaping ribbon for easy tip shapeability and core-to-tip design for excellent torque transmission for outstanding control and steering in challenging anatomy.

Read More