The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is a classic hybrid workhorse guide wire. It adopts a composite structure of proximal 304V stainless steel and distal nitinol alloy, delivering robust support, superior kink resistance and long-lasting durability. Featuring core-to-tip design and transitionless fusion weld technology, it achieves full-length 1:1 synchronous torque response for accurate and smooth manipulation. The distal 3 cm platinum-nickel radiopaque coil and long-acting hydrophilic coating greatly reduce friction for smooth advancement. The shapeable nitinol tip maintains stable shape during procedures. It navigates tortuous and stenotic peripheral vessels such as femoral artery, popliteal artery and infra-popliteal artery efficiently, serving as the primary choice for percutaneous transluminal angioplasty, stent implantation and other peripheral interventional procedures.
Intended Use :
PTATotal Length :
190cm / 250cm / 300cmOuter Diameter :
0.014” (0.36 mm)Distal Core Material :
NitinolTip Style :
Core-to-tipDistal Coatings :
HydrophilicTip Load (g) :
3.5Radiopaque length :
3cmTip Shape :
StraightUsage Type :
Single Use OnlyThe HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is meticulously developed for complex peripheral vascular interventions and acts as a core workhorse device for lower extremity vascular procedures. The high-strength 304V stainless steel core at the proximal end provides sufficient pushability and overall support to resist kinking. The distal Elastinite nitinol segment offers excellent flexibility and shape retention to adapt to diverse vascular anatomies. The transitionless fusion weld eliminates structural gaps and ensures smooth passage of balloons, stents and other interventional devices. The distal Pellathane hydrophilic coating minimizes friction against vessel walls and reduces the risk of vascular trauma. The 3 cm platinum-nickel radiopaque coil delivers outstanding fluoroscopic visibility for real-time tracking of wire position and depth. With integrated core-to-tip structure, it realizes lossless torque transmission and maintains stable performance in severely tortuous vessels and short-access lesions. It is widely applied for lesion crossing, device exchange and vascular access establishment.
The distal shapeable soft tip is available in straight and angled styles. A 3 cm platinum-nickel radiopaque coil is equipped at the distal end for clear fluoroscopic imaging. With a standard diameter of 0.014 inch and multiple optional lengths, the guide wire adopts composite hydrophilic coating. Sterilized by electron beam radiation, this is a single-use sterile medical device manufactured under strict standards.
| Coating | Distal: Hydrophilic; Proximal: PTFE |
| Core Material | Stainless Steel, Nitinol |
| Tip / Radiopacity | Platinum-Nickel Alloy, 3 cm Radiopaque Coil |
| Jacket / Cover | Full Polyurethane Polymer Cover |
| Usage | Single Use Only |

As a widely recognized workhorse guide wire for peripheral interventional specialists, this device is not intended for coronary or cerebral vasculature. It is mainly used for diagnosis and treatment of lower extremity peripheral vascular diseases:
Patient safety and consistent clinical performance are our core principles. The HI-TORQUE PILOT 50 Guide Wire is manufactured in state-of-the-art cleanrooms in strict accordance with the ISO 13485 medical device quality management system. Every batch undergoes rigorous tests including torque response, coating adhesion, kink resistance, tip shape durability and tensile strength to ensure reliable and stable performance in interventional labs. The product complies with mainstream global medical device safety standards and holds complete compliance qualifications to meet clinical access requirements of various regions.
We supply high-quality peripheral interventional consumables to hospitals, specialized interventional clinics and medical device distributors worldwide. Bulk orders and combined specification orders are supported, and customized services as well as OEM/ODM cooperation are available upon request. Please contact our sales team for wholesale pricing, shipping terms, lead time and regional compliance certification documents.
Yes. Adopting stainless steel and nitinol hybrid structure, it features excellent kink resistance and flexibility. Combined with low-friction hydrophilic coating, it can smoothly navigate tortuous lower extremity vessels such as femoral artery, popliteal artery and infra-popliteal artery, making it an ideal option for complex peripheral interventions.
No. This device is strictly designated for Single Use Only. Re-sterilization and reuse will damage the hydrophilic coating, hybrid core structure and tip performance, and may cause vascular injury, infection and other medical risks. Reuse is prohibited to ensure patient safety.
Absolutely. We partner with reliable international logistics providers to fulfill global B2B orders. Please reach out with your required volume for a customized quote and lead time estimate.