Enter product details (such as color, size, materials etc.) and other specific requirements to receive an accurate quote.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
product details

The BALANCE MIDDLEWEIGHT Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) guide wire is designed for kink resistance and durability. BMW family also features moderate support, excellent flexibility, shaping ribbon for easy tip shapeability and core-to-tip design for excellent torque transmission for outstanding control and steering in challenging anatomy.

  • Intended Use :

    PCI
  • Total Length :

    190cm / 300cm
  • Outer Diameter :

    0.014"
  • Distal Core Material :

    Nitinol
  • Cover Type or Coils :

    Bare Coils
  • Tip Style :

    Shaping Ribbon
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    0.6
  • Tip Shape :

    Straight / J
  • Usage Type :

    Single Use Only

Product Overview

The BALANCE MIDDLEWEIGHT (BMW) guide wire is meticulously designed for kink resistance and durability in complex clinical environments. The BMW family features moderate support, excellent flexibility, and a shaping ribbon for easy tip shapeability. Engineered with a core-to-tip design, it delivers outstanding torque transmission, ensuring optimal control and steering in challenging anatomy.


Key Highlights

  • Hydrophilic Coating: Premium Pellathane coating on the distal surface significantly reduces friction for smooth vessel navigation.
  • Excellent Torque Transmission: Advanced core-to-tip design ensures precise control and 1:1 torque response during manipulation.
  • Balanced Support & Flexibility: Ideal for traversing various complex coronary anatomies.
  • Soft & Shapeable Tip: Pre-formed J-shape (optional) and soft tip design enhance patient safety during interventional procedures.
  • Optimized Delivery: Perfectly suited for smooth balloon and stent (bracket) delivery.

Technical Specifications & Construction

The distal tip of this device is shapeable or pre-formed in a J-shape as an optional configuration. Radiopaque markers are precisely incorporated at the distal end for excellent fluoroscopic visibility.

Coating Pellathane Hydrophilic Coating (Distal Surface)
Core Material 304V Stainless Steel, Elastinite Nitinol Alloy
Tip / Radiopacity Platinum-Nickel Alloy
Jacket / Cover Polyurethane, PTFE (Polytetrafluoroethylene)
Usage Single Use Only
Clinical application of BMW guidewire in PCI

Typical Clinical Applications

Recognized as one of the most commonly used "first wires" by interventional cardiologists, this device is widely applied in:

  • Conventional Coronary PCI (Percutaneous Coronary Intervention)
  • Bracket / Stent Delivery
  • Balloon Passage and Dilatation
  • Bifurcation Lesions
  • Moderate Tortuosity Lesions
  • Initial Lesion Crossing

Quality Assurance & Compliance

Patient safety and clinical efficacy are our top priorities. The BALANCE MIDDLEWEIGHT UNIVERSAL guidewire is manufactured in state-of-the-art cleanrooms under strict quality management systems. Each batch undergoes rigorous testing for torque response, coating durability, and tensile strength to ensure consistent performance in the catheterization lab.


Ordering Information

We supply high-quality medical consumables to hospitals, clinics, and medical device distributors worldwide. Bulk ordering and customized specifications (OEM/ODM) are available upon request. Please contact our sales team to discuss wholesale pricing, shipping terms, and specific regional compliance documentation.


Frequently Asked Questions (FAQ)

1. Is the BMW guidewire suitable for tortuous anatomy?

Yes, the combination of an Elastinite nitinol alloy core and a hydrophilic coating provides excellent flexibility and kink resistance, making it highly effective for crossing moderate to complex tortuosity.

 

2. Can this guidewire be sterilized and reused?

No. To ensure maximum patient safety and preserve the integrity of the Pellathane hydrophilic coating, this medical device is strictly designated for Single Use Only.

 

3. Do you support global shipping and bulk orders?

Absolutely. We partner with reliable international logistics providers to fulfill global B2B orders. Please reach out with your required volume for a customized quote and lead time estimate.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Interventional Guidewire Supplier
The HI-TORQUE COMMAND 18 ST Hybrid Workhorse Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND 18 ST Guide Wire is a hybrid workhorse peripheral guide wire that combines the advantages of nitinol and stainless steel. It features high support, superior kink resistance and long-term durability. Equipped with a 10 cm nitinol segment at the distal end and a flexible tip with 4g tip load, the wire is easy to shape. Adopting parabolic core and transitionless weld design, it delivers highly efficient torque transmission. With balanced pushability, maneuverability and crossing performance, it can effectively cross occlusive lesions and complete subintimal looping procedures, serving as a core workhorse guide wire for lesion crossing and device delivery in peripheral vascular interventions of lower extremities.

Read More
Interventional Guidewire Supplier
The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire with Hydrophilic Coating

The HI-TORQUE COMMAND ES Workhorse Peripheral Guide Wire is a classic hybrid workhorse guide wire. It adopts a composite structure of proximal 304V stainless steel and distal nitinol alloy, delivering robust support, superior kink resistance and long-lasting durability. Featuring core-to-tip design and transitionless fusion weld technology, it achieves full-length 1:1 synchronous torque response for accurate and smooth manipulation. The distal 3 cm platinum-nickel radiopaque coil and long-acting hydrophilic coating greatly reduce friction for smooth advancement. The shapeable nitinol tip maintains stable shape during procedures. It navigates tortuous and stenotic peripheral vessels such as femoral artery, popliteal artery and infra-popliteal artery efficiently, serving as the primary choice for percutaneous transluminal angioplasty, stent implantation and other peripheral interventional procedures.

Read More
Interventional Guidewire Supplier
The HI-TORQUE PILOT 50 Specialty Guide Wire with Hydrophilic Coating

The HI-TORQUE PILOT 50 Guide Wire is a high-performance guide wire dedicated to coronary and peripheral vascular interventions. Constructed with DURASTEEL high-strength stainless steel core and full polymer cover, it delivers outstanding kink resistance and long-term durability. Adopting core-to-tip design, it realizes 1:1 accurate torque response for sensitive manipulation and stable steering. The distal 3 cm platinum-nickel radiopaque segment and durable PVP hydrophilic coating greatly reduce friction to ensure smooth advancement and withdrawal. With a lightweight 1.5g soft tip that is manually shapeable and optionally pre-formed into J-shape, it combines superior trackability and lesion crossing performance. It is capable of navigating tortuous vessels, severe stenosis and chronic total occlusions (CTO), serving as a primary workhorse guide wire for lesion crossing and device delivery in coronary and peripheral interventional procedures.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL II Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL II Guide Wire is a coronary workhorse guide wire developed by Abbott for PCI procedures. It is designed to provide an optimized balance of torque response, trackability, lubricity, and vessel support in routine and moderately complex coronary interventions.

Read More
Interventional Guidewire Supplier
The BALANCE MIDDLEWEIGHT UNIVERSAL Workhorse Guidewire with Hydrophilic Coating

The BALANCE MIDDLEWEIGHT (BMW) UNIVERSAL Guide Wire is a classic coronary intervention guide wire developed by Abbott, widely used for balloon and stent delivery in PCI/PTCA procedures. It is widely recognized worldwide as a "workhorse guidewire" for daily PCI procedures.