product details

High Rail Support 0.014” DURASTEEL Parabolic Hydrophilic PCI Guidewire for Complex Calcified & Long Coronary Lesions

HI-TORQUE WHISPER EXTRA SUPPORT (ES) adopts reinforced DURASTEEL parabolic tapered stainless core to deliver upgraded shaft rigidity and superior rail performance, engineered for demanding coronary lesions requiring powerful stent and balloon delivery support beyond WHISPER LS & medium-support variants. Equipped with full 25.6cm continuous Hydrocoat hydrophilic polymer jacket and 1.3g standardized tip load, it maintains atraumatic soft navigation while providing enhanced pushability for medium-to-heavy calcified stenosis and multi-stent long-segment procedures.

  • Outer Diameter :

    0.014"
  • Total Length :

    190cm / 300cm
  • Distal Core Material :

    Nitinol
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    1.3
  • Tip Shape :

    Straight / J
  • Usage Type :

    Single Use Only

Product Overview

Positioned as the highest-support tier within the WHISPER stainless core portfolio, WHISPER ES is purpose-built for complex coronary PCI scenarios where medium-support wires lack sufficient mechanical stability for bulky stent systems and long lesion tracking. The reinforced parabolic DURASTEEL taper eliminates rigid core transition points to resist buckling under moderate vessel torsion, while full polymer distal jacket with integrated Hydrocoat lubricant forms long-lasting low-friction film without coating shedding during repeated serial lesion crossing. A continuous 3cm platinum-nickel radiopaque coil delivers full fluoroscopic visualization for long-segment occlusions, balancing 1.3g mild atraumatic tip load and boosted shaft rigidity. This wire is contraindicated for cerebral neurovascular intervention and rotational atherectomy matching, and not recommended for ultra-fragile thin distal micro-branches with minimal plaque burden.


Key Highlights

  • Reinforced DURASTEEL Parabolic Taper Stainless Core: Upgraded core cross-section delivers maximum rail support of the entire WHISPER lineup, stabilizing large-diameter stent delivery through long calcified vasculature.
  • Full-Length Integrated Hydrocoat Hydrophilic Polymer Jacket: Extended continuous lubrication zone maintains consistent slippage for uninterrupted tracking of multi-segment serial coronary stenosis.
  • Balanced 1.3g Mild Tip Load & High Shaft Rigidity Combo: Soft atraumatic distal coil cuts intimal injury risk while reinforced core provides robust push force for partial CTO and dense calcified plaques.
  • 3cm Uninterrupted Platinum-Nickel Radiopaque Spring Coil: Long continuous marker segment achieves full lesion boundary localization under low-dose fluoroscopy, reducing radiation exposure for operators.
  • Core-To-Tip Lag-Free HI-TORQUE Torque Transmission: Seamless stainless core gradient delivers instant directional response during navigation of moderately tortuous complex bifurcations.

Technical Specifications & Construction

Two factory tip configurations: manually reshaping straight tip & factory pre-formed standard J tip; distal full Hydrocoat hydrophilic polymer cladding, proximal shaft covered wear-resistant PTFE hydrophobic outer jacket; 3cm fixed continuous platinum-nickel radiopaque coil at distal working segment.

Distal Coating Full Integrated Hydrocoat Hydrophilic Polymer Jacket
Proximal Coating PTFE hydrophobic coating
Core Material Stainless Steel, Elastinite Nitinol Alloy
Tip / Radiopacity 3cm Continuous Flexible Platinum-Nickel Alloy Radiopaque Spring Coil
Tip Style Core-to-tip
Usage Single Use Only


Typical Clinical Applications

High-support specialty PCI guidewire for complex coronary intervention cases requiring enhanced device delivery stability, covering five core high-demand lesion scenarios:

  • Multi-Stent Implantation for Long-Segment Moderately Calcified Coronary Stenosis
  • Complex True Bifurcation Lesion Treatment with Dual Balloon & Side Branch Stent Synchronized Delivery
  • Initial True Lumen Crossing for Medium-Density Partial Chronic Total Occlusion (CTO) Lesions
  • Heavy Drug-Eluting Stent Delivery in Moderately Tortuous Long Coronary Vasculature
  • Long-Distance Serial Stenosis Tracking for Multi-Vessel Combined Coronary Lesions

Quality Assurance & Compliance

All HI-TORQUE WHISPER EXTRA SUPPORT guidewires are manufactured in FDA & CE certified Class III cardiovascular clean production lines under full ISO13485 QMS supervision. Compared with WHISPER LS & medium-support MS variants, each batch undergoes exclusive high-load shaft cyclic buckling fatigue test and long-term Hydrocoat coating abrasion durability inspection. Complete raw material batch trace archives of DURASTEEL core, hydrophilic coating and platinum coil are permanently stored to support domestic NMPA and global multi-region medical device registration; every finished wire passes single-piece tip load, torque stability and full radiopacity inspection before packaging.


Ordering Information

Distributed globally to top-tier tertiary cardiac cath labs focusing on complex calcified PCI, multi-stent bifurcation intervention and partial CTO recanalization, plus professional cardiovascular medical device distributors worldwide. Long-term large-volume B2B bulk orders support customized J-tip forming angles and extended special length development; neutral OEM neutral packaging schemes are available upon formal written application. Contact Abbott cardiovascular dedicated sales team to obtain exclusive high-support wire tiered wholesale pricing and cross-border integrated logistics & regional registration document packages.


Frequently Asked Questions (FAQ)

1. What core performance gaps separate WHISPER ES from WHISPER LS and WHISPER MS?

WHISPER LS is ultra-floppy low-support for mild tortuous micro-branches (1.0g tip load); WHISPER MS delivers balanced medium rigidity for routine single-vessel PCI; WHISPER ES adopts reinforced thick DURASTEEL core with maximum rail support, 1.3g tip load, exclusively for long calcified lesions, multi-stent delivery and partial CTO crossing that insufficiently supported by LS/MS variants.

 

2. Can WHISPER EXTRA SUPPORT be used for severe fully calcified chronic total occlusion complete recanalization?

Not recommended. Its stainless core provides robust pushability for partial CTO, but lacks specialized high-penetration tip structure to break dense full calcified fibrous caps; clinicians shall select PILOT 150 / PILOT 200 series dedicated CTO crossing guidewires for heavy full occlusive lesions.

 

3. What factory standard length options are supplied for WHISPER ES, which fits ultra-long multi-segment coronary lesion tracking?

Standard factory specifications: 190cm & 300cm; the 300cm extended variant is optimized for uninterrupted full tracking of ultra-long multi-vessel serial stenosis; custom lengths from 180cm to 360cm are supported for long-term bulk B2B procurement orders.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Abbott Hi-Torque COMMAND 18 ST hybrid peripheral crossing guidewire
0.018” Nitinol-Stainless Hybrid Hydrophilic Guidewire for BTK, SFA & Complex Peripheral CTO Subintimal Tracking

adopts patented transitionless hybrid core combining 10cm distal nitinol segment and high-tensile Durasteel stainless proximal shaft, exclusively developed as 0.018-inch peripheral crossing wire for subintimal tracking and chronic total occlusion recanalization. The 4g low-load flattened shapeable tip paired full-length core-to-tip hydrophilic coating delivers balanced high pushability and soft atraumatic performance without compatibility conflict with large-bore 0.018” peripheral catheters.

Read More
Abbott COMMAND ES High Torque Peripheral Interventional Guidewire
High Torque Specialized Peripheral Vascular Hydrophilic Guidewire for Lower Limb, Renal & Iliac Artery Intervention

COMMAND ES is a torque-enhanced dedicated peripheral interventional guidewire built with high tensile monolithic stainless steel core, equipped with extended distal hydrophilic coating to deliver reliable manipulation for heavy calcified lower limb, renal and iliac artery occlusive lesions.

Read More
Abbott HI-TORQUE PILOT 50 1.3g low tip load coronary guidewire
0.014” Full Polymer Hydrophilic Guidewire for Distal Tiny Branches & Mild Sub-Total Occlusion

HI-TORQUE PILOT 50 adopts exclusive parabolic DURASTEEL stainless steel core paired with 25.6cm continuous distal hydrophilic polymer cladding, delivering industry-leading low 1.3g tip load to reduce endothelial trauma in fragile distal coronary vasculature. The core-to-tip seamless torque structure and 3cm long platinum radiopaque coil enable steady, atraumatic navigation for tortuous micro branches and partial occlusions unsuitable for medium-support universal wires.

Read More
Abbott standard BMW balanced medium support PCI guidewire
Balanced Medium Support Benchmark Hydrophilic PCI Guidewire for Routine Coronary Procedures

The classic BMW standard guidewire integrates balanced rigidity-flexibility and uninterrupted core-to-tip torque transmission, serving as the universal baseline navigation wire for all routine elective coronary PCI cases worldwide.

Read More
Abbott BMW UNIVERSAL II second-gen anti-kink PCI guidewire
Advanced Coronary Workhorse Guidewire for Complex PCI Procedures

BMW UNIVERSAL II is an advanced coronary workhorse guidewire engineered to provide an optimal balance of torque control, support, trackability and vessel safety. Designed for routine and complex PCI procedures, it enables reliable navigation through tortuous anatomy, bifurcation lesions and moderately calcified vessels.

Read More
Abbott BMW UNIVERSAL moderately complex PCI guidewire
Upgraded Balanced Medium Support Universal PCI Guidewire for Moderately Complex Coronary

BMW UNIVERSAL upgrades the classic standard BMW platform with extended distal hydrophilic coating and optimized anti-kink composite core to handle moderately complex coronary cases. Single platinum coil radiopaque distal segment provides excellent fluoroscopic visibility for calcified stenosis and simple chronic occlusive lesions that exceed the performance limit of standard BMW.

Read More