Enter product details (such as color, size, materials etc.) and other specific requirements to receive an accurate quote.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
product details

Advanced Coronary Workhorse Guidewire for Complex PCI Procedures

BMW UNIVERSAL II is an advanced coronary workhorse guidewire engineered to provide an optimal balance of torque control, support, trackability and vessel safety. Designed for routine and complex PCI procedures, it enables reliable navigation through tortuous anatomy, bifurcation lesions and moderately calcified vessels.

  • Outer Diameter :

    0.014"
  • Total Length :

    190cm / 300cm
  • Distal Core Material :

    Nitinol
  • Cover Type or Coils :

    Intermediate Polymer
  • Tip Style :

    Shaping Ribbon
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    0.6
  • Tip Shape :

    Straight / J
  • Usage Type :

    Single Use Only

Product Overview

Building upon the clinical success of the BMW platform, BMW UNIVERSAL II incorporates enhanced lubricity and optimized distal construction to improve lesion access and device delivery performance. The guidewire provides precise torque response, smooth vessel tracking and dependable support during balloon and stent deployment. Its versatile design allows operators to efficiently manage a wide range of coronary anatomies while maintaining excellent tactile feedback and procedural control.


Key Highlights

  • Improved Lubricity: Advanced coating technology reduces friction and enhances procedural efficiency.
  • Enhanced Trackability: Optimized distal construction facilitates smooth navigation through challenging vessel pathways.
  • Ultra-Sensitive 1:1 Synchronized Torque Transmission: Seamless integrated core connection eliminates torque delay, supporting precise steering for tortuous coronary anatomy.
  • Balanced Support Performance: Delivers sufficient support for balloon catheters and coronary stent delivery without sacrificing flexibility.
  • Reliable Vessel Safety: Soft atraumatic distal tip design helps reduce vessel trauma while maintaining procedural control.

Technical Specifications & Construction

Two optional tip configurations: manually shapable straight tip or factory pre-formed J-tip.

Coating Pellathane Hydrophilic Coating (Distal Surface)
Core Material 304V Stainless Steel, Elastinite Nitinol Alloy
Tip / Radiopacity Platinum-Nickel Alloy
Jacket / Cover Polyurethane, PTFE (Polytetrafluoroethylene)
Usage Single Use Only
Clinical application of BMW guidewire in PCI

Typical Clinical Applications

Second-generation high-performance universal workhorse guidewire for advanced complex coronary interventional treatment, suitable for the following high-difficulty PCI procedures:

  • PCI for Extensively Moderate Calcified Long-Segment Coronary Stenosis
  • Navigation for Severely Tortuous Vessels
  • Navigation for Complex True Bifurcation Lesions
  • Long-Distance Lesion Tracking During Multi-Stent Implantation Operations
  • Auxiliary Guidewire Support for Combined Hybrid PCI Procedures

Quality Assurance & Compliance

UNIVERSAL II undergoes comprehensive accelerated aging, cyclic kink fatigue and long-term coating abrasion testing exceeding standard medical device industry thresholds. All production links fully comply with ISO13485, FDA and CE Class II cardiovascular device standards.


Ordering Information

Supplied globally to top-tier tertiary cardiac hospitals, high-volume interventional cath labs and professional high-end cardiovascular medical distributors. Custom length OEM bulk cooperation orders are fully accepted. Contact the sales team to obtain tiered volume wholesale pricing and dedicated cross-border shipment support.


Frequently Asked Questions (FAQ)

1. Under what clinical scenarios should clinicians select UNIVERSAL II instead of standard BMW or first-gen UNIVERSAL?

Choose UNIVERSAL II when encountering moderate calcification, extreme vascular tortuosity and partial CTO lesions where standard BMW and first-gen UNIVERSAL cannot achieve smooth lesion crossing and stable steering.

 

2. What standard length specifications are available for routine clinical selection? Are custom lengths supported?

Standard specifications include 190cm and 300cm; 260cm extended lengths can be customized for ultra-long coronary lesion treatment upon large-volume order requests.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Abbott Hi-Torque COMMAND 18 ST hybrid peripheral crossing guidewire
0.018” Nitinol-Stainless Hybrid Hydrophilic Guidewire for BTK, SFA & Complex Peripheral CTO Subintimal Tracking

adopts patented transitionless hybrid core combining 10cm distal nitinol segment and high-tensile Durasteel stainless proximal shaft, exclusively developed as 0.018-inch peripheral crossing wire for subintimal tracking and chronic total occlusion recanalization. The 4g low-load flattened shapeable tip paired full-length core-to-tip hydrophilic coating delivers balanced high pushability and soft atraumatic performance without compatibility conflict with large-bore 0.018” peripheral catheters.

Read More
Abbott COMMAND ES High Torque Peripheral Interventional Guidewire
High Torque Specialized Peripheral Vascular Hydrophilic Guidewire for Lower Limb, Renal & Iliac Artery Intervention

COMMAND ES is a torque-enhanced dedicated peripheral interventional guidewire built with high tensile monolithic stainless steel core, equipped with extended distal hydrophilic coating to deliver reliable manipulation for heavy calcified lower limb, renal and iliac artery occlusive lesions.

Read More
Abbott HI-TORQUE PILOT 50 1.3g low tip load coronary guidewire
0.014” Full Polymer Hydrophilic Guidewire for Distal Tiny Branches & Mild Sub-Total Occlusion

HI-TORQUE PILOT 50 adopts exclusive parabolic DURASTEEL stainless steel core paired with 25.6cm continuous distal hydrophilic polymer cladding, delivering industry-leading low 1.3g tip load to reduce endothelial trauma in fragile distal coronary vasculature. The core-to-tip seamless torque structure and 3cm long platinum radiopaque coil enable steady, atraumatic navigation for tortuous micro branches and partial occlusions unsuitable for medium-support universal wires.

Read More
Abbott Hi-Torque Whisper Extra Support Guide Wire
High Rail Support 0.014” DURASTEEL Parabolic Hydrophilic PCI Guidewire for Complex Calcified & Long Coronary Lesions

HI-TORQUE WHISPER EXTRA SUPPORT (ES) adopts reinforced DURASTEEL parabolic tapered stainless core to deliver upgraded shaft rigidity and superior rail performance, engineered for demanding coronary lesions requiring powerful stent and balloon delivery support beyond WHISPER LS & medium-support variants. Equipped with full 25.6cm continuous Hydrocoat hydrophilic polymer jacket and 1.3g standardized tip load, it maintains atraumatic soft navigation while providing enhanced pushability for medium-to-heavy calcified stenosis and multi-stent long-segment procedures.

Read More
Abbott standard BMW balanced medium support PCI guidewire
Balanced Medium Support Benchmark Hydrophilic PCI Guidewire for Routine Coronary Procedures

The classic BMW standard guidewire integrates balanced rigidity-flexibility and uninterrupted core-to-tip torque transmission, serving as the universal baseline navigation wire for all routine elective coronary PCI cases worldwide.

Read More
Abbott BMW UNIVERSAL moderately complex PCI guidewire
Upgraded Balanced Medium Support Universal PCI Guidewire for Moderately Complex Coronary

BMW UNIVERSAL upgrades the classic standard BMW platform with extended distal hydrophilic coating and optimized anti-kink composite core to handle moderately complex coronary cases. Single platinum coil radiopaque distal segment provides excellent fluoroscopic visibility for calcified stenosis and simple chronic occlusive lesions that exceed the performance limit of standard BMW.

Read More