Enter product details (such as color, size, materials etc.) and other specific requirements to receive an accurate quote.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
product details

0.018” Nitinol-Stainless Hybrid Hydrophilic Guidewire for BTK, SFA & Complex Peripheral CTO Subintimal Tracking

adopts patented transitionless hybrid core combining 10cm distal nitinol segment and high-tensile Durasteel stainless proximal shaft, exclusively developed as 0.018-inch peripheral crossing wire for subintimal tracking and chronic total occlusion recanalization. The 4g low-load flattened shapeable tip paired full-length core-to-tip hydrophilic coating delivers balanced high pushability and soft atraumatic performance without compatibility conflict with large-bore 0.018” peripheral catheters.

  • Outer Diameter :

    0.018"
  • Total Length :

    210cm / 300cm
  • Distal Core Material :

    Nitinol
  • Tip Style :

    Core-to-tip
  • Distal Coatings :

    Hydrophilic
  • Tip Load (g) :

    4
  • Tip Shape :

    Straight
  • Usage Type :

    Single Use Only

Product Overview

As a professional hybrid crossing wire under Abbott Hi-Torque COMMAND 18 series, ST variant differentiates from LT navigation model via short 10cm distal nitinol hybrid structure to prioritize lesion penetration and subintimal loop prolapse capacity, targeting femoropopliteal, tibial BTK complex occlusive lesions. Parabolic grinding transition-free core eliminates torque attenuation during long-distance peripheral manipulation; integrated full polymer hydrophilic cladding maintains stable lubricity through calcified, tortuous long-segment vasculature. 3cm continuous platinum-nickel radiopaque coil ensures complete lesion visualization under low-dose fluoroscopy, while balanced hybrid rigidity avoids excessive shaft stiffness causing arterial wall perforation during hard plaque penetration. This wire is contraindicated for coronary and intracranial vascular procedures, solely designed for peripheral arterial interventional scenarios.


Key Highlights

  • 10cm Short Distal Nitinol Hybrid Core (ST Exclusive Spec): Shortened nitinol segment delivers boosted pushability & crossing force for rigid calcified peripheral CTOs, superior to 25cm nitinol LT model in subintimal prolapse efficiency.
  • Transitionless Weld Parabolic Core Design: Seamless metal transition realizes 1:1 lossless torque transmission from proximal shaft to flattened tip, no torsion lag during tortuous vessel steering.
  • 4g Low-Load Flattened Re-Shapable Nitinol Tip: Cold-formed flat tip retains shape after repeated subintimal looping, minimizes vessel dissection while sustaining stable penetration force.
  • Full Core-To-Tip Continuous Hydrophilic Polymer Coating: Entire working segment coated without segmentation friction gaps, durable lubricity for long-segment peripheral lesion tracking.
  • 3cm Extended Platinum-Nickel Radiopaque Spring Coil: Long continuous marker zone enables real-time full-length lesion positioning, reducing fluoroscopy radiation exposure for clinicians.

Technical Specifications & Construction

Single flattened manual shapeable tip (no factory J preform option); 10cm distal superelastic nitinol + proximal high tensile Durasteel stainless hybrid core; 3cm uninterrupted platinum-nickel radiopaque coil covers distal working segment for full lesion fluoroscopic tracking.

Coating Distal Hydrophilic Coating
Core Material Stainless Steel, Nitinol
Tip / Radiopacity Platinum-Nickel Alloy, 3 cm Radiopaque Segment
Jacket / Cover Full Polyurethane Polymer Cover
Usage Single Use Only


Typical Clinical Applications

Specialized hybrid crossing guidewire exclusively for peripheral arterial interventional radiologists & vascular surgeons, limited to lower-extremity peripheral PTA/CTO recanalization operations:

  • Subintimal Tracking & True Lumen Crossing for Femoropopliteal Long-Segment CTO Lesions
  • Calcified BTK Tibial Artery Occlusion Recanalization (Above & Below Knee Interventions)
  • Tight Loop Prolapse Operation for Severely Tortuous Peripheral Arterial Lesions
  • Large-Bore 0.018” Peripheral Balloon & Stent Stable Delivery Rail
  • Initial Crossing Wire for Moderate-Hard Plaque Iliac Artery Stenosis

Quality Assurance & Compliance

All Hi-Torque COMMAND 18 ST guidewires are manufactured on peripheral vascular medical device clean production lines, fully compliant with ISO13485, FDA 510(k) and CE MDR peripheral interventional regulatory standards. Independent hybrid core torsion fatigue, subintimal repeated shaping durability and long-term coating abrasion dedicated tests are added beyond general guidewire inspection standards. Every finished wire undergoes single-piece tip load & radiopacity inspection before packaging.


Ordering Information

Distributed globally to professional peripheral vascular surgery wards, dedicated peripheral interventional cath labs and global specialized PTA medical device distributors. Custom extended length specifications are available for bulk long-term B2B orders; standardized OEM neutral packaging solutions can be matched upon written demand. Contact exclusive peripheral sales representatives to obtain tiered bulk wholesale prices, cross-border peripheral medical logistics support and regional registration certification documents for PTA devices.


Frequently Asked Questions (FAQ)

1. What interventional procedures can the guidewire be applied to?

This wire only for peripheral lower-extremity arteries; its 0.018 large outer diameter and high crossing push force will raise coronary vessel dissection & perforation risk, BMW series coronary wires or other dedicated guidewires available on our platform can be selected for cardiac surgeries.

 

2. What core performance gap between COMMAND 18 ST and COMMAND 18 LT of the same series?

ST equips short 10cm distal nitinol hybrid segment for high crossing force & subintimal prolapse (target CTO recanalization); LT adopts 25cm long nitinol segment for ultra-flexible long-distance vessel tracking (target severe tortuous navigation scenarios). Both carry identical 4g soft tip load.

 

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Abbott COMMAND ES High Torque Peripheral Interventional Guidewire
High Torque Specialized Peripheral Vascular Hydrophilic Guidewire for Lower Limb, Renal & Iliac Artery Intervention

COMMAND ES is a torque-enhanced dedicated peripheral interventional guidewire built with high tensile monolithic stainless steel core, equipped with extended distal hydrophilic coating to deliver reliable manipulation for heavy calcified lower limb, renal and iliac artery occlusive lesions.

Read More
Abbott HI-TORQUE PILOT 50 1.3g low tip load coronary guidewire
0.014” Full Polymer Hydrophilic Guidewire for Distal Tiny Branches & Mild Sub-Total Occlusion

HI-TORQUE PILOT 50 adopts exclusive parabolic DURASTEEL stainless steel core paired with 25.6cm continuous distal hydrophilic polymer cladding, delivering industry-leading low 1.3g tip load to reduce endothelial trauma in fragile distal coronary vasculature. The core-to-tip seamless torque structure and 3cm long platinum radiopaque coil enable steady, atraumatic navigation for tortuous micro branches and partial occlusions unsuitable for medium-support universal wires.

Read More
Abbott Hi-Torque Whisper Extra Support Guide Wire
High Rail Support 0.014” DURASTEEL Parabolic Hydrophilic PCI Guidewire for Complex Calcified & Long Coronary Lesions

HI-TORQUE WHISPER EXTRA SUPPORT (ES) adopts reinforced DURASTEEL parabolic tapered stainless core to deliver upgraded shaft rigidity and superior rail performance, engineered for demanding coronary lesions requiring powerful stent and balloon delivery support beyond WHISPER LS & medium-support variants. Equipped with full 25.6cm continuous Hydrocoat hydrophilic polymer jacket and 1.3g standardized tip load, it maintains atraumatic soft navigation while providing enhanced pushability for medium-to-heavy calcified stenosis and multi-stent long-segment procedures.

Read More
Abbott standard BMW balanced medium support PCI guidewire
Balanced Medium Support Benchmark Hydrophilic PCI Guidewire for Routine Coronary Procedures

The classic BMW standard guidewire integrates balanced rigidity-flexibility and uninterrupted core-to-tip torque transmission, serving as the universal baseline navigation wire for all routine elective coronary PCI cases worldwide.

Read More
Abbott BMW UNIVERSAL II second-gen anti-kink PCI guidewire
Advanced Coronary Workhorse Guidewire for Complex PCI Procedures

BMW UNIVERSAL II is an advanced coronary workhorse guidewire engineered to provide an optimal balance of torque control, support, trackability and vessel safety. Designed for routine and complex PCI procedures, it enables reliable navigation through tortuous anatomy, bifurcation lesions and moderately calcified vessels.

Read More
Abbott BMW UNIVERSAL moderately complex PCI guidewire
Upgraded Balanced Medium Support Universal PCI Guidewire for Moderately Complex Coronary

BMW UNIVERSAL upgrades the classic standard BMW platform with extended distal hydrophilic coating and optimized anti-kink composite core to handle moderately complex coronary cases. Single platinum coil radiopaque distal segment provides excellent fluoroscopic visibility for calcified stenosis and simple chronic occlusive lesions that exceed the performance limit of standard BMW.

Read More