0.014” Dual-Core Tungsten Radiopaque Wire for Coronary PTCA & Peripheral PTA

PT² Moderate Support adopts segmented dual-core architecture combining proximal 304V stainless steel and linear elastic nitinol distal segment connected via INCONEL alloy coupler, paired with exclusive long ICE hydrophilic sleeve to deliver balanced rigidity and flexibility. The moderate rail support design ensures steady device delivery in mild calcified, tortuous coronary and peripheral arteries, while limited 2cm shapeable distal zone avoids over-manipulation injury to thin vessel intima.

  • Outer Diameter :

    0.014 inch (0.36 mm)
  • Total Length :

    185 cm / 300 cm
  • Distal Coatings :

    Hydrophilic
  • Radiopaque length :

    2cm
  • Tip Shape :

    Straight / J
  • Usage Type :

    Single Use Only

Product Overview

As mid-strength benchmark of PT² guidewire portfolio, Moderate Support variant is developed for universal daily coronary and peripheral interventional scenarios, differentiated from Light Support ultra-soft model by enhanced shaft resilience for mild resistant lesions. The 30cm full tungsten-doped polymer outer sleeve integrated with proprietary ICE lubricant forms persistent low-friction film after repeated lesion crossing, with 2cm terminal moldable zone reserved for customized vessel matching. Linear elastic nitinol distal segment serves as core anti-kink structure to prevent shaft buckling under moderate vessel torsion; proximal PTFE coating cuts friction during catheter back-and-forth exchange. Equipped with continuous tungsten radiopacity without metal spring coil, the wire delivers clear lesion positioning under routine fluoroscopy. This device is strictly contraindicated for all cerebral neurovascular interventional operations.


Key Highlights

  • Dual-Segment Hybrid Core with INCONEL Transition Joint: Proximal rigid stainless steel provides stable rail support, distal linear elastic nitinol suppresses kinking under vessel bending.
  • 30cm Full Tungsten-Doped Polymer Sleeve with Exclusive ICE Coating: Long continuous lubrication segment retains slippage after multiple serial stenosis passage without coating peeling.
  • Continuous Tungsten Radiopacity Without Metal Spring Coil: Uniform X-ray visibility across full distal working zone, no imaging blind spot compared with segmented platinum coil wires.
  • Moderate Balanced Rail Support Profile: Optimized shaft hardness matches standard bare metal & drug-eluting stents as well as semi-compliant balloon delivery workflows.
  • Limited 2cm Distal Shapeable Zone: Restricted molding range prevents excessive tip stiffness that triggers arterial dissection in fragile vasculature.

Technical Specifications & Construction

Two factory tip options: manually shapeable straight tip / factory pre-formed gentle J tip; only the terminal 2cm of distal sleeve supports secondary manual shaping; 30cm tungsten-doped polymer outer sleeve coated with ICE hydrophilic lubricant, proximal shaft covered by wear-resistant PTFE jacket.

Coating Distal: Hydrophilic; Proximal: PTFE
Core Material Stainless Steel, Nitinol
Tip / Radiopacity Platinum-Nickel Alloy
Jacket / Cover Polymer
Usage Single Use Only



Typical Clinical Applications

Universal daily workhorse guidewire for general interventional cardiologists and peripheral vascular surgeons, suitable for mild-complex coronary & peripheral PTA procedures:

  • Elective Single-Vessel Routine Coronary PTCA & Stent Implantation
  • Mild Tortuous Vessel & Simple True Coronary Bifurcation Lesion Crossing
  • Non-Calcified / Mild Calcified Serial Coronary Stenosis Tracking
  • Femoral & Iliac Artery Mild Stenosis PTA & Balloon Dilatation
  • Initial Wire Navigation for Routine Diagnostic Coronary & Peripheral Angiography

Quality Assurance & Compliance

All PT² Moderate Support guidewires are manufactured within FDA/CE certified cardiovascular clean production lines under full ISO13485 QMS control. Beyond standard torsion fatigue and coating friction testing, each batch undergoes exclusive dual-core bending durability and tungsten radiopacity stability inspection.


Ordering Information

Distributed worldwide to community general hospitals, routine cardiac cath labs and peripheral vascular interventional clinics, alongside global general medical device distributors. Medium & large bulk procurement can enjoy tiered volume discount; neutral OEM packaging scheme is available upon formal written application. Contact our dedicated sales representatives to acquire exclusive wholesale pricing, cross-border one-stop logistics and regional registration certification packages.


Frequently Asked Questions (FAQ)

1. What clinical difference between PT² Moderate Support and PT² Light Support?

Moderate Support adopts reinforced hybrid core for mild calcified coronary and peripheral lesions with medium rail support; Light Support features softer nitinol matching ultra-fragile thin coronary vessels without enough pushing force for mild calcified plaques.

 

2. Can PT² Moderate Support guidewire be used for cerebral angiography or stroke recanalization?

Strictly prohibited. The moderate shaft rigidity and tungsten sleeve thickness may raise intracranial vessel dissection risk; dedicated neuro interventional guidewires must be selected for all cerebrovascular procedures.

 

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products